How to Debug Fully Automatic Folding Mask Machine
Your old friend Shandong Lujia Machinery Technology Co., Ltd. will tell you how to debug the Fully Automatic Folding Mask Machine today.
1. Turn on the start and stop switch and the power switch, the built-in light of the power switch is on.
2. Adjust the air pressure: the air pressure valve is under the worktable, and the air pressure valve can be seen by opening the door panel of the equipment. Adjust the pressure according to the actual situation. Increase the pressure when some mechanisms are out of sync. The working air pressure is generally adjusted within the range of 0.2~0.6MPa.
Red tube technology welding earband part
3. Sonic inspection and adjustment: (when the equipment is stopped)
(1) Turn on the power switch of the ultrasonic generator, and press the "Sonic Wave Inspection" switch. If the indicator of the amplitude display rises sharply and exceeds 100, it means that the frequency is too far from the resonance point, and the "Sonic Wave Adjustment" knob must be adjusted. Visually look at the amplitude display, press the "Sound Wave Test" check switch with the left hand (no more than 3 seconds), turn the "Sound Wave Adjustment" knob with the right hand, and adjust the pointer of the amplitude display to the lowest point. When adjusting, if the indicator of the amplitude display is not falling, but rising, turn the "Sound Wave Adjustment" knob in the opposite direction. The reading of the amplitude display indicator is within 50, and the reading of the ammeter indicator is below 0.6A is the best working state. After adjusting the sound wave, tighten the wing nut and close the protective cover.
(2) During the no-load test, if the "overload indicator light" is on, it means that there is a problem with the equipment. At this time, it is not allowed to start up and work. It is necessary to shut down the machine to check the cause, and then start up and work after troubleshooting.
4. Inspection of cooling fan: Check whether the cooling fan is working normally to ensure that the ultrasonic transducer can work for a long time during operation.
5. Check the pneumatic components:
(1) Turn on the power supply, connect the air circuit, and switch the manual and automatic switch to manual gear.
2) Turn on the ear strap cutting switch, and check whether the ear strap cutting small cylinder works and can reach the designated cutting position.
3) Turn on the ear strap return switch, check whether the ear strap return small cylinder can work normally, and can loosen the ear strap clamp block.
4) Turn on the switch of the mask clipping fixture to check whether the mask clipping fixture operates normally. After the inspection, turn off the switch of the mask clamping fixture.
(5) Turn on the switch of the collecting cylinder to check whether the collecting cylinder operates normally. After checking, turn off the switch of the aggregate cylinder.
6) Turn on the tray switch to check whether the tray can run quickly and stably and be positioned accurately. Turn off the tray switch after checking
7) Turn on the left switch of the ear strap rotation to see if the left rotary cylinder is in motion and the action is in place.
8) Turn on the sideband welding switch to see if the sideband stamper can be pressed down normally.
9) Turn on the right switch of the ear strap rotation, and see if the rotating cylinder on the right is moving and the movement is in place.
(10) Turn on the ear strap welding switch to check whether the ear strap stamper can work and reach the designated position.